ISO 13802

Plastics - Verification of pendulum impact-testing machines - Charpy, Izod and tensile impact-testing
Plastics - Verification of pendulum impact-testing machines - Charpy, Izod and tensile impact-testing
Plastics - Verification of Pendulum Impact-Testing Machines - Charpy, Izod and Tensile Impact-Testing

: ISO

: 1110000211295

:

Format
$199.00

Publication Date: 06/01/2015 - Complete Document *

Description :

This International Standard specifies frequency and methods for the verification of pendulum impacttesting machines used for the Charpy impact test, Izod impact test, and tensile impact test described in ISO 179-1, ISO 180, and ISO 8256, respectively. Verification of instrumented impact machines is covered insofar as the geometrical and physical properties of instrumented machines are identical to non instrumented machines. The force/work verification of instrumented machines is not covered in this International Standard.

This International Standard is applicable to pendulum-type impact-testing machines, of different capacities and/or designs, with the geometrical and physical properties defined in Clause 5.

Methods are described for verification of the geometrical and physical properties of the different parts of the test machine. The verification of some geometrical properties is difficult to perform on the assembled instrument. It is, therefore, assumed that the manufacturer is responsible for the verification of such properties and for providing reference planes on the instrument that enable proper verification in accordance with this International Standard.

These methods are for use when the machine is being installed, has been repaired, has been moved, or is undergoing periodic checking.

A pendulum impact-testing machine verified in accordance with this International Standard, and assessed as satisfactory, is considered suitable for impact testing with unnotched and notched test specimens of different types.

Annex A details design requirements for Charpy testing machines.

Annex B details design requirements for Izod testing machines.

Annex C details design requirements for tensile impact machines.

Annex D explains how to calculate the ratio of frame mass to pendulum mass required to avoid errors in the impact energy.

Annex E explains deceleration of pendulum during impact. Annex F details design requirements for one type of gauge used to verify striker and anvil/support alignment for Charpy testing machine.

Document Type : Complete Document

Edition : Second Edition; Corrected version 04/01/2016

Language : English

Page Count : 40

Publication Date : 06/01/2015

Revision : 2ND

Status : Current

Title : Plastics - Verification of pendulum impact-testing machines - Charpy, Izod and tensile impact-testing

Publication Date: 06/01/2015 - Base Document *

Description :

This International Standard specifies frequency and methods for the verification of pendulum impacttesting machines used for the Charpy impact test, Izod impact test, and tensile impact test described in ISO 179-1, ISO 180, and ISO 8256, respectively. Verification of instrumented impact machines is covered insofar as the geometrical and physical properties of instrumented machines are identical to non instrumented machines. The force/work verification of instrumented machines is not covered in this International Standard.

This International Standard is applicable to pendulum-type impact-testing machines, of different capacities and/or designs, with the geometrical and physical properties defined in Clause 5.

Methods are described for verification of the geometrical and physical properties of the different parts of the test machine. The verification of some geometrical properties is difficult to perform on the assembled instrument. It is, therefore, assumed that the manufacturer is responsible for the verification of such properties and for providing reference planes on the instrument that enable proper verification in accordance with this International Standard.

These methods are for use when the machine is being installed, has been repaired, has been moved, or is undergoing periodic checking.

A pendulum impact-testing machine verified in accordance with this International Standard, and assessed as satisfactory, is considered suitable for impact testing with unnotched and notched test specimens of different types.

Annex A details design requirements for Charpy testing machines.

Annex B details design requirements for Izod testing machines.

Annex C details design requirements for tensile impact machines.

Annex D explains how to calculate the ratio of frame mass to pendulum mass required to avoid errors in the impact energy.

Annex E explains deceleration of pendulum during impact.

Annex F details design requirements for one type of gauge used to verify striker and anvil/support alignment for Charpy testing machine.

Document Type : Base Document

Edition : Second Edition

Language : English

Page Count : 42

Publication Date : 06/01/2015

Revision : 2ND

Status : Historical

Title : Plastics - Verification of pendulum impact-testing machines - Charpy, Izod and tensile impact-testing

Publication Date: 10/15/1999 - Complete Document Changes Incorporated *

Document Type : Complete Document

Edition : First Edition; Technical Corrigendum 1 04/15/2000

Language : English

Page Count : 42

Publication Date : 10/15/1999

Revision : 1ST

Status : Historical

Supplement : W/

Title : Plastics - Verification of Pendulum Impact-Testing Machines - Charpy, Izod and Tensile Impact-Testing